There are many ways to measure a bore, and many factors that influence the accuracy of hole diameter measurements. For example, we know that operator skill in using rocking-type adjustable bore gages can influence the results, as can variations in part geometry. This may make even technically accurate measurements inaccurate from a part-function perspective, so it is important to consider the effects of gage centralization for smaller bores. Selecting the right tool is often based on the bore’s size and tolerance.

One of the fundamental requirements in bore gaging is that the gage contacts be centered in the bore. Bore gages that are not properly centered measure a chord of the circle rather than its true diameter. Operator error is a common cause of poor centralization with rocking-type gages, while wear or damage can affect the centralization of any gage.

An adjustable bore gage may be the gage of choice for bores with a tolerance of 0.002" or more. Most adjustable bore gages have a centralizer that helps the operator align the gage properly, and with good operator skill, good results can be obtained. However, should the centralizer or sensitive contact be damaged, there will be a likelihood of some gage influence on the results. Centralization errors can be checked by comparing the results of mastering on a ring gage and then checking with end standards.

Once tolerances start to get less than 0.001", a fixed-body plug gage is apt to be right for the application. Fixed-body plug gages, such as mechanical two-point plug gages or two-jet air plugs (or air rings), are designed to be self-centering. These fixed-body gages are designed with very specific clearances based on the combination of bore size and tolerance. The engineered clearance between the gage body and the nominal size of the bore is really a compromise between ease of insertion and optimum centralization to reduce this error.

Centralization error is the difference between the true diameter and the length of the chord measured. Quality personnel and gage designers specify centralization error as a percentage of a gaging operation’s total error budget (or repeatability requirement). For example, the error budget might be 10% of the tolerance. In addition to an allowance for centralization error, this might include influences of operator error, gage repeatability, environmental variation and within-part variation (for example, geometry error).

Photo Credit: Mahr Inc.

Gage manufacturers and users must be prepared to calculate how far off the bore center line a gage may be without exceeding the specified centralization error. Let’s call the allowable distance between the bore center line and the contact center line the misalignment (clearance) tolerance. A simple formula based on the relationship between the legs and the hypotenuse of a right triangle does the job:

                x2 = z2 - y2

where:

                x = misalignment tolerance

                y = z - 1/2 centralization error

                z = 1/2 nominal diameter

Let’s run through an example. The nominal bore dimension is 0.5", with a dimensional tolerance of 0.0002" (±0.0001"). Since the goal may be to get the total gage error to less than 10% of tolerance, it would not be unreasonable to let centralization error be specified at a maximum of 2% of the dimensional tolerance (or 0.02 x 0.0002" = 0.000004").

                z = 0.5" ÷ 2 = 0.250"

                y = 0.250" - (0.00004" ÷ 2) = 0.249998"

                x2 = (0.250")2 - (0.24998")2

                x2 = 0.0625" - 0.062499"

                x2 = 0.000001"

                x = 0.001"

The gage must have less than 0.001" clearance or be off-center before it exceeds the allowable centralization error. If you run through the same exercise for a 5.0" nominal bore, keeping the other values constant, you’ll find that misalignment can be up to 0.0031" before centralization error exceeds 2% of the 0.0002" dimensional tolerance. Thus, as bore size increases, so does the misalignment tolerance. But on the other hand, measuring smaller bores with a tight tolerance requires very tight clearances to eliminate centralization errors.

For the smaller diameters — say, less than 1" — it is important to monitor this error. As one can expect, with years of use measuring hundreds of thousands of parts, the plug may become worn, resulting in excessive clearance and poor centralization.

Checking centralization is easy for self-centering gage types. To check a two-contact or two-jet plug, insert the gage horizontally into a master ring, allowing the master to bear the gage’s weight. For an air ring, one can do the same test with the master disc. Measure once with the contacts or jets oriented vertically and once horizontally. If the measurements differ, and a significant portion of the tolerance, it may be time to replace.

Wenzel
VERISURF
Koma Precision
Precision Components
CHIRON Group, one stop solution for manufacturing.
High Accuracy Linear Encoders
Paperless Parts
Mazak - Innovative manufacturing for medical
World Machine Tool Survey
IMTS 2024
benchmark international advanced manufacturing trade show
Starrett 2900 Series Digital Indicator

Related Content

How to Calibrate Gages and Certify Calibration Programs

Tips for establishing and maintaining a regular gage calibration program.

Read More
Measurement

Help Operators Understand Sizing Adjustments

Even when CNCs are equipped with automatic post-process gaging systems, there are always a few important adjustments that must be done manually. Don’t take operators understanding these adjustments for granted.

Read More
Workholding

Parts and Programs: Setup for Success

Tips for program and work setups that can simplify adjustments and troubleshooting.

Read More
Basics

Rethink Quality Control to Increase Productivity, Decrease Scrap

Verifying parts is essential to documenting quality, and there are a few best practices that can make the quality control process more efficient.

Read More

Read Next

3 Mistakes That Cause CNC Programs to Fail

Despite enhancements to manufacturing technology, there are still issues today that can cause programs to fail. These failures can cause lost time, scrapped parts, damaged machines and even injured operators.

Read More
Shop Management Software

5 Tips for Running a Profitable Aerospace Shop

Aerospace machining is a demanding and competitive sector of manufacturing, but this shop demonstrates five ways to find aerospace success.

Read More
Wenzel